TABLE FOR THE CHOICE OF THE INJECTORS
Natural gas Propane gas
Test Point Pressure [kPa] 1.0 2.75
BURNER
Auxiliary (A) 0.85 3.60 0.53 3.60
Semi-rapid (SR) 1.12 6.30 0.70 6.30
Triple ring (TC) 1.65
13.30
0.95 11.90
Gas
Consumption
[MJ/h]
Injector
Orifice Dia.
[mm]
Gas
Consumption
[MJ/h]
Injector
Orifice Dia.
[mm]
13
LUBRICATION OF THE GAS TAPS
If the gas tap becomes stiff, it is necessary to dismantle it carefully and clean it with petroleum
spirit. Specialist high temperature resistant grease should be used to lubricate the tap before
replacing.
The operations must be carried out by an authorised person/service agent.
Figure 11